Instruction Manual
13
To install casters:
Casters are supplied as oponal equipment. Only use genuine casters or the base
of the cooler might suer damages. When installing the casters it is important to
hand ghten securely against the base rail reinforcement assembly (see image). The
top edge of the caster must make rm contact with the reinforcement assembly.
Each unit requires a 110 Volt individual, properly grounded branch circuit
with a 3 prong grounding type receptacle, protected by a 15 or 20 Amp
circuit breaker or me-delay fuse.
Electrical installaon must be in accordance with Naonal Electrical Codes
and local ordinances.
ELECTRICAL INSTALLATION
Caster
Base rail
NOTE:
Casters with hand-brakes must be placed in FRONT of the unit.
Hand-brake