Instructions to Replace Compressor.
17. Remove the
compressor from the
base rails.
18. Not all compressor removal
requires cleaning the low and
high sides of the system.
However, if you suspect that
there are high levels of
contamination, sweep the
system using dry nitrogen at
250 psig.
19. Place the new
compressor on the
base rails
20. Insert the four clips,
pins and washers in
the base of the
compressor to hold it
in place to the base
rails.
DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE