9. First disconnect the two black wires connecting the
starting capacitor and the blue color wire of the start
relay. Then use a slotted screwdriver as a pry bar to pull
out the relay / overload protector assembly from the
compressor shell.
10. To install the new relay / overload protector assembly
reverse the previous steps.
Instruction to Replace Start Relay, Overload Protector
DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE