Refrigerator User Manual

29
3. Cabinet Defrost Alarm (E3)
Once the defrost termination temperature is reached, the signal from the defrost
thermistor should terminate the defrost. If the defrost thermistor does not terminate the
defrostwithin100minutes(1hourand40minutes),"E3"isdisplayed.When"E3"is
displayed, the next step in the defrost process begins.
Reset Options
To reset the alarm, turn the power off and then back on.
Possible Causes (forfurtherdetailssee"III.B.ServiceChart")
•Troublewiththedefrostheater.
•Troublewiththedefrostthermistor.
•Troublewiththecontrolboard.