Service Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- II. General Information
- A. Construction
- B. Sequence of Operation
- C. Control Board
- 1. Control Board Layout
- 2. LED Lights and Audible Alarm Safeties
- 3. Controls and Adjustments
- a) Default Dip Switch Settings
- b) Harvest Timer (S4 dip switch 1 & 2)
- c) Pump-Out Timer (S4 dip switch 3 & 4)
- d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
- e) Harvest Pump Timer (S4 dip switch 7)
- f) Factory Use (S4 dip switch 8)
- g) Freeze Timer (S4 dip switch 9 & 10)
- h) Float Switch Control (S5 dip switch 1)
- i) Refill Counter (S5 dip switch 2 through 5)
- D. Control Switch
- III. Technical Information
- IV. Service Diagnosis
- V. Replacement of Components
- VI. Cleaning and Maintenance
42
3. Low Ice Production
Low Ice Production - Possible Cause
Long Harvest Cycle
1. Evaporator a) Scaled up.
2. Spray Tubes and/or Spray
Guides
a) Dirty.
b) Out of position.
3. Refrigerant Charge a) Low.
4. Water Supply a) Low water pressure.
b) External water lters clogged.
c) Insufficient water line size.
Minimum1/4"nominalIDcopperwatertubingorequivalent.
d) Too cold.
5. Control Board
See "IV.B.ControlBoardCheck"
a) Thermistor connection loose (K3).
b) Defective.
6. Thermistor
See"IV.E.ThermistorCheck"
a) Loose, disconnected, or defective.
7. Hot Gas Valves (KMS & SRK) a) Erratic or closed.
8. Inlet Water Valve a) Screen or orice clogged.
9. Compressor a) Inefficient or off.
10. Liquid Line Valves (KMS & SRK) a) Erratic or open.
11. Termostatic Expansion Valve
(TXV)
a) Defective.
12. Headmaster (C.P.R.) a) Defective.
Long Freeze Cycle
1. Evaporator a) Scaled up, dirty.
2. Float Switch
See"IV.D.FloatSwitchCheck
andCleaning"
a) Scaled up, dirty.
b) Float sticking.
c) Defective switch.
3. Inlet Water Valve a) Leaking by.
4. Hot Gas Valves (KMS & SRK) a) Erratic or open.
5. Condenser a) Clogged.
6. Control Board
See "IV.B.ControlBoardCheck"
a) Float switch connection loose (K5).
b) Defective.
7. Refrigerant Charge a) Low.
8. Thermostatic Expansion Valve
(TXV)
a) Bulb loose.
b) Defective.
9. Compressor a) Inefficient or off.
10. Pump Motor a) RPM too slow.
11. Liquid Line Valves (KMS & SRK) a) Erratic or closed.
12. Headmaster (C.P.R.) a) Not bypassing.