13) Replace the insulation panel, then replace the left side, top, and front panels in their
correct positions.
14) Turn on the power supply to start the automatic icemaking process.
Legend: CB–control board; F/S–oat switch
E. Thermistor Check
To check thermistor resistance, follow the steps below.
1) Turn off the power supply.
2)Removethefrontpanel,thenmovethecontrolswitchtothe"OFF"position.
3) Remove the control box cover.
4) Remove the thermistor.
5) Immerse the thermistor sensor portion in a glass containing ice and water for 2 or
3 minutes.
6) Disconnect the thermistor connector from CB K3 (white) connector and check
resistance between thermistor leads. Normal range is 4.7 to 6.2 kΩ. If outside the
normalrange,replacethethermistor.See"V.B.ImportantNotesforComponent
Replacement."Ifwithinthenormalrange,continuetonextstep.
7)Replacethethermistorinitscorrectposition.See"V.B.ImportantNotesforComponent
Replacement."
8) Reconnect the thermistor connector to CB K3 (white) connector.
9) Replace the control box cover in its correct position.
10)Movethecontrolswitchtothe"ICE"position.
11) Replace the front panel in its correct position.
12) Turn on the power supply.
13) Once the harvest cycle starts (Comp energizes), begin timing the harvest cycle.
14) The harvest timer and harvest cycle should terminate within 2 to 5 minutes. If the
harvest cycle does not terminate within 2 to 5 minutes, replace CB.
Legend: CB–control board, Comp–compressor