Service Manual

Table Of Contents
20
c) Pump-Out Timer (S4 dip switch 3 & 4)
NOTICE
Do not adjust S4 dip switch 3& 4 to 3 off and 4 on. Otherwise, pump motor
does not rotate in the pump-out direction.
When a pump-out is called for, the pump motor de-energizes for 2seconds, then
energizes for 10/20 seconds in reverse direction. Water is removed from the bottom of
the water tank and sent down the drain through the check valve. At the same time, water
ows through the small F/S tube to power ush F/S. The pump-out drains the water tank
for the time determined by the pump-out timer. The pump-out timer also acts in place
of the harvest timer during cycles with a pump-out. The pump-out timer is factory set,
and generally no adjustment is required. However, where water quality is bad and the
icemaker needs a longer pump-out, the pump-out timer can be adjusted. The pump-out
timer (S4 dip switch 3 & 4) can be set to have a 10 or 20 second pump-out.
S4 Dip Switch Setting Time (seconds)
Inlet
Water
Valve
No. 3 No. 4
T1
T2
OFF OFF 10 150 closed
ON OFF 10 180 closed
OFF ON 10 120 open
ON ON 20 180 closed
T1: Time to drain the water tank
T2: Harvest timer at pump-out
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump-out frequency control is factory-adjusted to drain the water tank every
10cycles, and generally no adjustment is required. However, where water quality is bad
and the icemaker needs a more frequent pump-out, the pump-out frequency can be
adjusted as shown in the table below.
Timing of the rst pump-out is dependent on S4 dip switch 5 & 6 settings. See the table
below.
S4 Dip Switch Setting
Pump-Out
Frequency
1st Pump-Out
No. 5 No. 6
OFF OFF Every cycle After 2nd freeze cycle
ON OFF Every 2 cycles After 3rd freeze cycle
OFF ON Every 5 cycles After 6th freeze cycle
ON ON Every 10 cycles After 11th freeze cycle