15
2. Sequence Flow Chart
F/S check
1 to 3-min. timer in control
(S4 dip switch 1 & 2)
"G" Control Board Sequence Flow Chart
1. 1-Minute Fill
Cycle
Cycle Steps
2. Harvest Cycle
•WVtime:6min.orthelengthofharvestminus50sec.
(S4 dip switch 7), whichever is shorter. DO NOT
ADJUST S4 dip switch 7.
•Maximumharvesttime:20min.
Thermistor
in control
3. Freeze Cycle
•Minimumfreezetime:5min.
•Maximumfreezetime:freezetimersetting
(S4 dip switch 9 & 10)
F/S in control
4. Pump-Out Cycle
•Factorysetforevery
10th cycle
(S4 dip switch 5 & 6)
•PMstopsfor2sec.,
then reverses for
10/20 sec.
(S4 dip switch 3 & 4)
DO NOT ADJUST S4
dip switch 3 and 4 to
3 off and 4 on.
WV energized
F/S open
WV continues
Comp energized
FMR energized
HGVs energized
Thermistor temperature
reaches 48°F (9°C)
(3.9 kΩ or less).
Harvest timer starts.
F/S open
Comp continues
FMR continues
PM continues
LLVs energized
HGVs de-energized
F/S closed
Comp continues
FMR continues
PM de-energized for 2 sec., then
energized in reverse
direction for 10/20 sec.
HGVs energized
LLVs de-energized
F/S check
Startup begins
here after 5-sec.
delay
If F/S is open, Comp and FMR de-energize and cycle returns to 1-Minute Fill Cycle
5-min. timer in
control
F/S closed
F/S open or freeze
timer terminates
50 sec.
PM energized
WV de-energized
Harvest Pump
Timer
KMS-830MLH with SRK-8H/3
Legend:
BC–bin control
Comp–compressor
FMR–fan motor-remote
F/S–oat switch
HGVs–hot gas valves (KMS and SRK)
LLVs–liquid line valves (KMS and SRK)
PM–pump motor
WV–inlet water valve
1. Bin Full
Shutdown Delay:
•Fill Cycle – 15 sec. after activation.
•Harvest Cycle – At the end of the harvest cycle, or up to 15 sec. into the
freeze cycle if activated at the end of the harvest cycle.
•Freeze Cycle – 15 sec. after activation if activated at least 15 sec. before
the 5-min. short cycle protection timer terminates.
Otherwise, at the end of the next harvest cycle.
Shutdown
andRestart
BC Operation
BC open
Green"BCCLOSED"LEDoff
Yellow"BCOPEN"LEDon
Yellow"BCOPEN"LEDcontinues
All components de-energized
2. Icemaker Off
All components
de-energized.
3. Ice Level Lowered
Ice level lowered. No ice
pressing against BC actuator
paddle. Icemaker starts at
"1.1-MinuteFillCycle."
To 1 above
BC closed
Green"BCCLOSED"LEDon
Yellow"BCOPEN"LEDoff
Components Energized when the Control Switch is in the "WASH" Position
The"WASH"positiononthecontrolswitchisusedwhencleaningandsanitizingtheunit.Wheninthe"WASH"position,
power is supplied to the pump motor. With the cleaning valve closed, the cleaner and sanitizer ow over the outside of
the evaporator plate assembly. With the cleaning valve open, the cleaner and sanitizer ow over both the outside and the
inside of the evaporator plate assembly.
Note: Close the cleaning valve after cleaning and sanitizing are complete, otherwise the unit will not re-start when the
controlswitchisplacedinthe"ICE"position.