d) Pump-Out Cycle
LEDs 1, 3, and 2 are on. LED 4 is on when S4 dip switch 3 & 4 are set to 3 off and 4 on.
Fordetails,see"II.C.3.c)Pump-OutTimer(S4dipswitch3&4)."NOTICE! Do not
adjust S4 dip switch 3 & 4 to 3 off and 4 on. Adjustment to this position on this
model prevents the pump motor from rotating in the pump-out (reverse) direction.
Comp and FMR remain energized, HGVs energize. LLVs de-energize. PM de-energizes
for 2 seconds, then energizes in reverse direction for 10 seconds. Water is removed
from the bottom of the water tank and sent down the drain through the check valve. At
the same time, water ows through the small F/S tube to power ush F/S. When the
pump-out timer terminates, pump-out is complete.
The pump-out timer and pump-out frequency control are factory set, and generally no
adjustmentis required. However, where water quality is bad and the icemaker needs
a longer and/or more frequent pump-out, the pump-out timer and pump-out frequency
control can be adjusted. The pump-out timer (S4 dip switch 3 & 4) can be set to have a
10or20secondpump-out.Fordetails,see"II.C.3.c)Pump-OutTimer(S4dipswitch3&
4)."Thepump-outfrequencycontrol(S4dipswitch5&6)canbeadjustedasshownin
thetablebelow.Fordetails,see"II.C.3.d)Pump-OutFrequencyControl(S4dipswitch
5&6)."Timingoftherstpump-outisdependentonS4dipswitch5&6settings.See
the table below.
S4 Dip Switch Setting
Pump-Out
Frequency
1st Pump-Out
No. 5 No. 6
OFF OFF Every cycle After 2nd freeze cycle
ON OFF Every 2 cycles After 3rd freeze cycle
OFF ON Every 5 cycles After 6th freeze cycle
ON ON Every 10 cycles After 11th freeze cycle
e) Harvest Cycle
Sameastheinitialharvestcycle.See"II.B.1.b)InitialHarvestCycle."
Note: Unit continues to cycle until BC is satised or power is turned off. The unit always
restarts at the 1-minute ll cycle.
f) Shutdown
WhenBCisactivated(BCopen),yellow"BCOPEN"LEDturnson.Theunitthenshuts
down as outlined in the table below.
Cycle at Bin
Control Activation
Shutdown
Fill Cycle 15 seconds after activation.
Harvest Cycle At the end of the harvest cycle, or up to 15 seconds into the freeze cycle if activated
at the end of the harvest cycle.
Freeze Cycle 15 seconds after activation if activated at least 15 seconds before the 5-minute short
cycle protection timer terminates. Otherwise, at the end of the next harvest cycle.
Legend: BC–bin control; CB–control board; Comp–compressor; FMR–fan motor-remote;
F/S–oat switch; HGVs–hot gas valves (KMS and SRK); LLVs–liquid line valves
(KMS and SRK); PM–pump motor; WV–inlet water valve; X10–pump motor
direction relay; X11–X10 control relay