Service Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- II. General Information
- A. Construction
- B. Sequence of Operation
- C. Control Board
- 1. Control Board Layout
- 2. LED Lights and Audible Alarm Safeties
- 3. Controls and Adjustments
- a) Default Dip Switch Settings
- b) Harvest Timer (S4 dip switch 1 & 2)
- c) Pump-Out Timer (S4 dip switch 3 & 4)
- d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
- e) Harvest Pump Timer (S4 dip switch 7)
- f) Factory Use (S4 dip switch 8)
- g) Freeze Timer (S4 dip switch 9 & 10)
- h) Float Switch Control (S5 dip switch 1)
- i) Refill Counter (S5 dip switch 2 through 5)
- D. Control Switch
- III. Technical Information
- IV. Service Diagnosis
- V. Replacement of Components
- VI. Cleaning and Maintenance
10
2. SRK-8H3
AC SUPPLY VOLTAGE 208-230/60/3
(115VAC Supplied to KMS via Factory Wire Harness)
AMPERAGE 7.5 A ( 5 Min. Freeze AT 104°F / WT 80°F )
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
EXTERIOR DIMENSIONS (WxDxH) 33.6"x23"x22.1" (854x585x562 mm)
DIMENSIONS INCLUDING LEGS (WxDxH) 35.7"x25.4"x37.1" (907x645x942 mm)
EXTERIOR FINISH Galvanized steel
WEIGHT Net 176 lb. (80 kg) Shipping 206 lb. (93 kg)
CONNECTIONS - ELECTRIC Main Power Supply: Permanent Connection
SRK to KMS: Wire Harness Connection
- REFRIGERANT Liquid Line 1/2" Copper Tube Field Connection
Suction Line 5/8" Copper Tube Field Connection
COMPRESSOR Hermetic, Model CS10K6E-TF5-255
CONDENSER Air Cooled, Fin and Tube Type
COMPRESSOR PROTECTION Auto-Reset Overload Protector (Internal)
FAN MOTOR PROTECTION Thermal Protection
REFRIGERANT CIRCUIT PROTECTION Auto-Reset High-Pressure Switch
Auto-Reset Discharge Line Thermostat
REFRIGERANT CONTROL Headmaster (C.P.R.) (160 PSIG)
REFRIGERANT CHARGE 13 lb. 10.7 oz. (6200g))
(Condensing Unit 13 lb. 3.6 oz. (6000g))
(Icemaker 0 lb. 7.1 oz. (200g))
DESIGN PRESSURE High 467 PSIG, Low 230 PSIG
OPERATING CONDITIONS VOLTAGE RANGE 187-253VAC
AMBIENT TEMP. (Outdoor use) -20-122°F
ACCESSORIES -SUPPLIED Leg 2 pcs
Hex Head Bolt w/Washer M8x16 8 pcs
Hex Nut M8 8 pcs
-REQUIRED Compatible KMS Icemaker
ENG.F-032.1.0205
Note: We reserve the right to make changes in specications and design without prior
notice.