Service Manual

Table Of Contents
39
2. Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reaches 48°F (9°C) at the
evaporator outlet and the control board reads 3.9 kΩ from the thermistor. The harvest
timer is factory set, and generally no adjustment is required. However, a setting longer
than the factory setting may be advised in cases where the drain provided at harvest
needs to be prolonged for extra cleaning. Before changing this setting, contact Hoshizaki
Technical Support at 1-800-233-1940 for recommendations. Keep in mind that setting the
harvest timer to a longer setting decreases 24-hour production.
Note that the pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump out. For details, see "III.C.3. Pump-Out Timer/Harvest Time
During Pump-Out (S4 dip switch 3& 4)."
Note: On models with a pump-out every cycle, the harvest timer is only relevant during
the initial harvest cycle since a pump out occurs every cycle thereafter.
S4 Dip Switch Setting Time
(sec.)
No. 1 No. 2
OFF OFF 60
ON OFF 90
OFF ON 120
ON ON 180
3. Pump-Out Timer/Harvest Time During Pump-Out (S4 dip switch 3 & 4)
NOTICE
On models with harvest pump timer, do not adjust 3 off and 4 on. Pump does not
run in pump-out rotation in this setting.
When a pump-out is called for, the pump motor stops for 2 sec. After 2 sec. the drain
valve and pump motor energize. Water is removed from the bottom of the water tank
and sent down the drain. The pump-out drains the water tank for the time determined by
the pump-out timer. The pump-out timer also acts in place of the harvest timer during
cycles with a pump-out. The pump-out timer is factory set, and generally no adjustment
is required. However, where water quality is bad and the icemaker needs a longer
pump-out time, the pump-out timer can be adjusted. The pump-out timer control can be
set to pump-out for 10 or 20 sec.
S4 Dip Switch Setting Time (sec.)
Inlet Water
Valve
No. 3 No. 4
T1 T2
S5-4 OFF S5-4 ON S5-4 OFF S5-4 ON
OFF OFF 10 150 100 Closed Closed
ON OFF 10 180 130 Closed Closed
OFF ON 10 120 70 Open Closed
ON ON 20 180 180 Closed Closed
T1: Time to drain the water tank
T2: Harvest timer at pump out