- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Harvest Timer (S4 dip switch 1 & 2)
- 3. Pump-Out Timer/Harvest Time During Pump-Out (S4 dip switch 3 & 4)
- 4. Pump-Out Frequency Control (S4 dip switch 5)
- 5. Harvest Pump Time (Harvest Assist Duration) (S4 dip switch 6)
- 6. Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (S4 dip switch 7)
- 7. Factory Use (S4 dip switch 8)
- 8. Freeze Timer (S4 dip switch 9 & 10)
- 9. Float Switch Control Selector (S5 dip switch 1)
- 10. Refill Counter (S5 dip switch 2 and 3)
- 11. Minimum Harvest Time (S5 dip switch 4)
- 12. Anti-Slush (S5 dip switch 5)
- IV. Refrigeration Circuit and Component Service Information
- VII. Disposal
- VIII. Technical Information
18
7) Pump-Out Cycle – LEDs 1, 3, and 2 are on (10/20 second pump-out). Timing of the
rst pump-out is determined by S4 dip switch 5. See the table below.
Control Board Settings
S4 Dip Switch Setting
Pump-Out Frequency Control Board
No. 5
OFF Every 10 cycles After 11th freeze cycle
ON Every cycle After 2nd freeze cycle
Comp and FMRs continue, HGVs energize.
Note: If S4 dip switch 3 & 4 are set to 3 off and 4 on, LED 4 turns on and WV and X11
relay energize, energizing X10 relay. NOTICE!S4dip switch 3 & 4 must not be set
to 3 off and 4 on. Otherwise, LED 4 turns on energizing WV and X11 relay. X11
relay energizes X10 relay. Once X10 relay energizes, X12 relay cannot energize.
Preventing DV from energizing.
LLVs de-energize. PM stops for 2 sec., then restarts for 10/20 sec. depending on
pump-out timer (S4dip switch 3 & 4) setting. When the pump-out timer terminates,
pump-out is complete. The pump-out frequency control (S4 dip switch 5) is factory set,
and generally no adjustment is required. However, the pump-out frequency control can
be set to have a pump-out occur every 10 cycles or every cycle. For details, see "III.C.4.
Pump-Out Frequency Control (S4 dip switch 5)."
a) Pump-Out Diagnosis: In the freeze cycle before pump-out (see table above), after
5min. of freeze disconnect CB black K5 connector (FS connector). Check that CB
LEDs 1, 3, and 2are on, PM stops, then restarts, DV energizes, and water is owing
down the drain through DV.
b) CB Diagnosis: Conrm LLVs de-energize. If LLVs are energized with LEDs 1, 3,
and 2 on, replace CB. If PM does not stop and restart and DV does not energize,
check that CB LEDs 1, 3, and 2 are on. Ifnot, replace CB. IfLEDs 1, 3, and 2 are on
and X12 relay is not energized, check for 115VAC at CB K1 #5 (DBU) to neutral(W).
If115VAC is not present, replace CB. If115VAC is present at CB K1 #5 (DBU) and
X12 relay is not energized, continue to "c) X12 Relay Diagnosis:" below. If X12
relay is energized and DV are not energized, check for 115VAC at CB K1 #2 (P) to
neutral(W). If LED 2 is on and 115VAC is not present at CB K1 #2 (P), replace CB.
c) X12 Relay Diagnosis: If 115VAC is present at CB K1 #5 (DBU) and CB K1 #2 (P)
and X12 relay and DV are not energized, check for 115VAC at X12 relay #8 (P) to
neutral (W). If115VAC is not present, check wiring connections from CB K1 #5 (DBU)
to X12 relay #6 (DBU), then at X12 relay #4 (W/R). If 115VAC is present at X12 relay
#6 (DBU) and not at X12 relay #4 (W/R), conrm X12 relay is de-energized, if X12
relay is de-energized, replace X12 relay (sticking contacts). If 115VAC is present
at X12 relay #5 (DBU) to neutral (W), and X12 is de-energized, check relay coil
continuity. Replace as needed.