Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagrams
- II. Sequence of Operation and Service Diagnosis
- III. Settings and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Harvest Time (S4 dip switch 1 & 2)
- 3. Pump-Out Time/Harvest Time During Pump-Out (S4 dip switch 3 & 4)
- 4. Pump-Out Frequency Control (S4 dip switch 5)
- 5. Harvest Pump Time (Harvest Assist Duration) (S4 dip switch 6)
- 6. Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (S4 dip switch 7)
- 7. Factory Use (S4 dip switch 8)
- 8. Freeze Timer (S4 dip switch 9 & 10)
- 9. Float Switch Control Selector (S5 dip switch 1)
- 10. Refill Counter (S5 dip switch 2 and 3)
- 11. Minimum Harvest Time (S5 dip switch 4)
- 12. Anti-Slush (S5 dip switch 5)
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
20
7) Pump-Out Cycle – LEDs 1, 3, and 2 are on (10/20 second pump-out). Timing of the
rst pump-out is determined by S4 dip switch 5. See the table below.
Control Board Settings
S4 Dip Switch Setting
Pump-Out Frequency Control Board
No. 5
OFF Every 10 cycles After 11th freeze cycle
ON Every cycle After 2nd freeze cycle
Comp and FMRs continue, HGVs energize.
Note: If S4 dip switch 3 & 4 are set to 3 off and 4 on, LED 4 turns on and WV2 and X12
relay energize, energizing X13 relay. NOTICE!S4dip switch 3 & 4 must not be set to
3 off and 4 on. Otherwise, LED 4 turns on energizing WV2, X12, and X13 relays.
Once X13 relay energizes, DV cannot energize.
LLVs de-energize. PM stops for 2 sec., then restarts for 10/20 sec. depending on
pump-out timer (S4dip switch 3 & 4) setting. When the pump-out timer terminates,
pump-out is complete. The pump-out frequency control (S4 dip switch 5) is factory set,
and generally no adjustment is required. However, the pump-out frequency control
can be set to have a pump-out occur every cycle. For details, see "III.C.4. Pump-Out
Frequency Control (S4 dip switch 5)."
a) Pump-Out Diagnosis: In the freeze cycle before pump-out (see table above), after
5min. of freeze disconnect CB black K5 connector (FS connector). Check that CB
LEDs 1, 3, and 2are on, PM stops, then restarts, DV energizes, and water is owing
down the drain through DV.
b) CB Diagnosis:
PM: If PM does not stop and restart, check that CB LEDs 1, 3, and 2are on.
Ifnot and pump-out is called for, replace CB. IfLEDs 1, 3, and 2are on, X11 relay
energizes. If not, check for 115VAC at CB K1 #5 (DBU) to neutral(W). If115VAC is
not present, replace CB. If115VAC is present at CB K1 #5 (DBU) and X11 relay is not
energized, continue to "c) PM Diagnosis:" below.
DV: If DV is not energized, check for 115VAC at CB K1 #1(V) to neutral(W).
If LED 2 is on and 115VAC is not present at CB K1 #1 (V), replace CB. If 115VAC is
present at CB K1 #1 (V) to neutral (W), continue to "d) DV Diagnosis" below.
c) PM Diagnosis: If 115VAC is present at CB K1 #5 (DBU), X11 relay energizes. Check
for 115VAC at X11 relay #8 (DBU) to neutral (W). If115VAC is not present, check
wiring connections from CB K1 #5 (DBU) to X11 relay #8 (DBU). If115VAC is present
at X11 relay #8 (DBU) and PM does not restart, check for 115VAC at X11 relay
terminal #4 (P) and terminal #(6) to neutral (W). If115VAC is present on #4 (P) and
not on #6 (R), replace X11 relay (sticking contacts). If 115VAC is present at X11 relay
#6 (R) and PM is de-energized, check for 115VAC at control switch
#6 (R) and #5(W/R) to neutral (W). If 115VAC is present at #6 (R) and not at
#5 (W/R), replace control switch. If 115VAC is present at control #5 (W/R), check PM
capacitor, motor winding, wiring connections, and impeller for binding.