Instructions Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- II. Installation and Operating Instructions
- III. Maintenance
- IV. Preparing the Appliance for Periods of Non-Use
- V. Disposal
25
I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the appliance is turned off, wait for at least 3 minutes before restarting the
appliance to prevent damage to the compressor.
• To prevent damage to the water pump, do not leave the control switch in the
"SERVICE" position when the water tank is empty.
• At startup, conrm that all internal and external connections are free of leaks.
• The remote condensing unit must have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
1) If removed, replace all panels except the front panel in their correct positions. If not
already removed, remove the front panel.
2) Open the water supply line shut-off valve.
3) Move the control switch to the "ICE" position. See Fig. 12. Replace the front panel in its
correct position.
4) Turn on the power supply, and allow the water tank to ll and the icemaker to operate for
a total of 10 minutes.
5) Move the control switch to the "OFF" position, then turn off the power supply.
6) Remove the front, apron, top, left side, and side insulation panels.
7) Remove the drain plug. Allow the water tank to drain.
Fig. 12
Drain Plug
Control Switch
Service Switch