Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Harvest Timer (S4 dip switch 1 & 2)
- 3. Pump-Out Timer (S4 dip switch 3 & 4)
- 4. Pump-Out Frequency Control (S4 dip switch 5 & 6)
- 5. Harvest Pump Timer Operation (S4 dip switch 7)
- 6. Factory Use (S4 dip switch 8)
- 7. Freeze Timer (S4 dip switch 9 & 10)
- 8. Float Switch Selector (S5 dip switch 1)
- 9. Refill Counter (S5 dip switch 2, 3, and 5), Program Selector (4)
- D. Switches
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
44
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
a) "G" Control Board without Harvest Pump Timer Operation
S4 Dip Switch
Model Auxiliary Code 1 2 3 4 5 6 7 8 9 10
KML-250MAH B-1 and Later
OFF OFF OFF ON ON ON OFF OFF ON OFF
KML-250MWH B-1 and Later OFF OFF OFF ON ON ON OFF OFF OFF ON
KML-351MWH C-1 and Later ON OFF ON ON OFF OFF OFF OFF OFF ON
KML-451MAH B-1 and Later OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
KML-451MWH B-1 and Later ON OFF OFF OFF ON ON OFF OFF OFF ON
KML-631MAH B-1 and Later ON OFF OFF OFF ON ON OFF OFF OFF ON
KML-631MWH C-0 and Later ON OFF OFF OFF ON ON OFF OFF OFF ON
KML-631MRH C-0 and Later ON OFF OFF OFF ON ON OFF OFF OFF ON
b) "G" Control Board with Harvest Pump Timer Operation
S4 Dip Switch
Model Auxiliary Code 1 2 3 4 5 6 7 8 9 10
KML-351MAH V-1 and Later OFF OFF OFF OFF OFF OFF ON OFF OFF ON
KMD-460MAH All ON OFF OFF OFF ON ON ON OFF OFF OFF
KMD-460MWH All OFF OFF OFF OFF ON ON ON OFF OFF OFF
KMD-530MAH All OFF OFF OFF OFF ON ON ON OFF OFF OFF
KMD-530MWH All OFF OFF OFF OFF ON ON ON OFF OFF OFF
KMD-530MRH All OFF OFF OFF OFF ON ON ON OFF OFF OFF
c) Float Switch Selector, Rell Counter, Program Selector
S5 Dip Switch (Do Not Adjust)
Model
1 2 3 4 5
All Models OFF OFF OFF OFF OFF
1 2 3 4 5
ON
1 2 3 4 5 6 7 8 9 10
ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Harvest Pump Timer (7) (Do not adjust)
Factory Use (8)
S4 Dip Switch
Do Not Adjust
S5 Dip Switch
Rell Counter
(2, 3, and 5)
Float Switch
Selector (1)
Program
Selector (4)