FS check
1 to 3-min. harvest timer in
control (S4 dip switch 1 & 2)
• Max. inlet water valve time: 6 min. or the length of
harvest minus 50 sec. (S4 dip switch 7), whichever is shorter.
• Max. harvest time: 20 min.
FS check
Legend:
Comp–compressor
DV–drain valve
FM–fan motor
FMR–fan motor-remote
FS–oat switch
HGV–hot gas valve
LLV–liquid line valve
PM–pump motor
WV–inlet water valve
"G" Control Board with Harvest Pump Timer Operation Sequence Flow Chart
1. 1-Minute
Fill Cycle
Cycle
Steps
2. Harvest Cycle
Thermistor in
control
3. Freeze Cycle
• Min. freeze time: 5 min.
• Max. freeze time: freeze timer setting
(S4 dip switch 9 & 10)
FS in control
4. Pump-Out Cycle
WV energized
FS open
Comp energized
FMR energized
HGV energized
WV energized
Thermistor temperature reaches
48°F (9°C) (3.9 kΩ or less). Harvest
timer starts (1 to 3 min.).
FS open
Comp continues
FMR continues
FM energized
LLV energized
PM energized
HGV de-energized
FS closed
Startup
If FS is open, Comp stops and cycle returns to 1-min. ll.
5-min. minimum
freeze timer in
control
FS closed
FS opens or
freeze timer
terminates
Harvest Pump
Timer
50 sec.
PM energized
WV de-energized
2. "G" Control Board with Harvest Pump Timer Operation
Shutdown and Restart See "II.A.3. Thermostatic and Mechanical Bin Control Shutdown Operation"
Comp continues
FMR continues
HGV energized
PM de-energizes for 2 sec.,
then DV and PM energize
for 10/20 sec.
FM de-energized
LLV de-energized
• Every 1, 2, 5, or 10
cycles
(S4 dip switch 5 & 6)
• Pump motor stops for
2 sec., then energizes
for 10/20 sec.
(S4 dip switch 3 & 4)
Components Energized when the Control Switch is in the "SERVICE" Position
When in the "SERVICE" position, the control switch supplies power to the service switch and the machine is in service mode.
The service switch has three positions: "DRAIN," "CIRCULATE" and "WASH." See the information below for details of each
function.
DRAIN
Power is supplied to the pump motor and drain valve. This drains the water tank.
CIRCULATE
Power is supplied to the pump motor only. This can be used to circulate cleaner over the
outside surface of the evaporator for extended periods of time.
WASH
Power is supplied to the pump motor and wash valve. This is used to circulate cleaner and
sanitizer over both the inside and outside surfaces of the evaporator.