13
2. Shutdown Flow Chart
1. Bin Full
Within 10 sec. after ice contacts
BC bulb, icemaker shuts down.
Shutdown
and Restart
BC
Operation
Ice contacts BC bulb
2. Icemaker Off
All components
de-energized.
3. Ice Level Lowered
No ice touching BC bulb.
Icemaker starts at
"1. 1-Minute Fill Cycle."
BC closed
BC open
All components
de-energized
To 1. 1-Minute Fill Cycle
NOTE: Green "BC CLOSED" LED
on continuously when K4
jumper is in place.
Shutdown Flow Chart
Legend:
BC–bin control