I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. KMH-2100S_/3
Single Phase
Model Number KMH-2100SRJ
AC Supply Voltage 208-230/60/1
Compressor 208-230V 10.9RLA 73LRA
Pump 120V 1.2FLA 60W
Fan 120V 3A MAX (Fans in
URC)
Other 115V 0.3A
Maximum Fuse Size 30 AMPS
Max. HACR Breaker
(USA Only)
30 AMPS
Max. Circuit Breaker
(Canada Only)
30 AMPS
Minimum Circuit
Ampacity
30 AMPS
Design Pressure HI-467PSI LO-230PSI
Refrigerant 404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit URC-22F:
16 LB. 1.5 OZ.
Three Phase
Model Number KMH-2100SWJ3 KMH-2100SRJ3
AC Supply Voltage 208-230/60/3 208-230/60/3
Compressor 208-230V 8.4RLA 66LRA 208-230V 7.9RLA 66LRA
Pump 120V 1.2FLA 60W 120V 1.2FLA 60W
Fan --- --- --- 120V 3A MAX (Fans in
URC)
Other 115V 0.3A 115V 0.3A
Maximum Fuse Size 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS
Design Pressure HI-427PSI LO-230PSI HI-467PSI LO-230PSI
Refrigerant 404A
3 LB. 1.4 OZ.
404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit URC-22F:
16 LB. 1.5 OZ.