19
KMH-2100SRJ/3
Fig. 8
Remote Condenser
Line Set Connections
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air
gap between the end of each pipe
and the drain.
Icemaker Water Supply
Line Shut-Off Valve
Icemaker Water Supply Line
Drain Valve
Icemaker
Icemaker
Water Supply
Inlet
1/2" FPT
Bin Drain Outlet
See Manufacturer's Instructions
2-inch (5-cm) air gap
Floor
Drain
Icemaker
Drain Outlet
3/4" FPT
Ice
Storage
Bin
Vent Tube
Minimum 1/2" Nominal Copper Water Tubing
Minimum 3/4" Nominal Hard Pipe
Condensation
Drain Outlet
3/8" OD Hard Tube
Vent Tube
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
Condensation
Drain Outlet
1/2" Female Pipe
Thread (FPT)
3/8" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
3/8" OD Hard
Tube
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.