Service Manual

Table Of Contents
15
Legend:
Comp–compressor
FM–fan motor
FMR–fan motor-remote
HGV–hot gas valve
PM–pump motor
WV–inlet water valve
2A7664-02 Freeze-Time Correction Flow Chart
1. 10-Minute Harvest Cycle with WV
• Do not adjust S4 dip switch 7 out of the factory position.
After step 2 completes 4th sequence (80 min. completed), repeat
step 1 for 5th and nal time.
Cycle Steps
Steps 1 and 2 repeat
4 times (total 80 min.),
then step 1 repeats for
a 5th time to complete
Freeze-Time Correction
Cycle.
2. 10-Minute Fill/Overow
Comp energized
FMR energized
HGV energized
PM energized
WV energized
WV energized
Comp de-energized
FMR de-energized
HGV de-energized
PM de-energized
Start
After 5th 10-Minute Harvest Pump Cycle with WV
Freeze-Time Correction Cycle Complete.
Go to Step "3. Freeze Cycle" in Operation Flow Chart.
Freeze Time Differential Exceeded.
Minimum and Maximum Freeze times have
exceeded differential parameters.
Freeze-Time Correction function is enabled
when S4 Dip Switch 7 is in the "ON" position.
CB monitors freeze time. After 3freeze cycles,
CB compares the minimum and maximum
differential of the 3 freeze cycle times. Every
freeze cycle time after the third freeze cycle
time is added to the minimum/maximum
calculation.
Example: After 8 cycles, if the differential
between the shortest cycle (minimum) and the
longest cycle (maximum) is equal to or greater
than 427 sec. a freeze-time correction cycle is
initiated:
Number of
Freeze Cycles
Differential
Value in Sec.
3 254
4 309
5 349
6 380
7 406
8 427
9 446
10 462
Note: When 1st freeze-time correction cycle
is initiated, CB "POWER OK" LED starts
blinking. On 2nd freeze-time correction cycle,
if CB "POWER OK" LED has been reset,
CB "POWER OK" LED starts blinking. If CB
"POWER OK" had not been reset after 1st
freeze-time correction cycle CB "POWER OK"
LED continues to blink.
After 3rd freeze-time correction cycle in
36hours, CB yellow "EXT HARVEST" LED
starts blinking.
Appliance continues to operate and LEDs
continue to blink until ALARM RESET button is
pressed with power on.
Appliance Cycle Reset and Alarm Reset:
Cycle Reset: Power Supply or Control Switch Turned Off and On again:
Appliance turns off, then re-starts at 1.Fill Cycle.
Alarm Reset: CB "ALARM RESET" pressed during or after a freeze-time
correction cycle with power supply on:
Appliance continues cycle with no interruption or reset.
CB red "POWER OK" LED blinking:
CB red "POWER OK" LED resets to solid.
CB yellow "EXT HARVEST" LED blinking:
CB yellow "EXT HARVEST: LED turns off.
3. Freeze-Time Correction Chart