Instructions

26
12) Close the condenser water supply line drain valve. If connected to a closed loop
system, also close the condenser return line drain valve.
2. Remove the water from the icemaker water supply line:
1) Turn off the power supply and remove the front panel.
2) Move the control switch on the control box to the “OFF” position.
3) Close the icemaker water supply line shut-off valve and open the icemaker water
supply line drain valve. See Fig. 9, 10 or 11.
4) Allow the line to drain by gravity.
5) Attach compressed air or carbon dioxide supply to the icemaker water supply line drain
valve.
6) Move the control switch to the “ICE” position.
7) Replace the front panel in its correct position and turn on the power supply.
8) Blow the icemaker water supply line out using compressed air or carbon dioxide
supply.
9) Close the icemaker water supply line drain valve.
3. Drain the water tank:
1) Turn off the power supply and remove the front panel.
2) Move the control switch to the “SERVICE” position and move the service switch to the
“DRAIN” position.
3) Replace the front panel in its correct position and turn on the power supply for 2
minutes.
4) Turn off the power supply and remove the front panel.
5) Move the control switch to the “OFF” position.
6) Replace the front panel in its correct position.
7) Remove all ice from the dispenser unit/storage bin. Clean the dispenser unit/storage
bin using a neutral cleaner. Rinse thoroughly after cleaning.
8) Close the icemaker water supply line drain valve.