Instructions
21
NOTICE
Be sure to let the discharge hose pass behind the copper tube and connect
it securely in position. See Fig. 12. Otherwise, the discharge hose may be
caught in the front insulation, leading to improper results.
9) Pour the cleaning solution into the water tank.
10) Move the service switch to the "WASH" position.
11) Replace the front insulation and the front panel in their correct positions.
Fig. 13
Fig. 12
Discharge
Hose
Float Switch
Connector
Pump Motor
Connector
Thumbscrews
Snap Tab
Pump Motor Bracket
Float Switch
Pump Motor
Cube Guide
Snap Tab