Instructions

18
I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect
safety, performance, component life, and warranty coverage.
NOTICE
1. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
2. To prevent damage to the water pump, do not leave the control switch in
the “SERVICE” position for extended periods of time when the water tank is
empty.
3. At startup, confirm that all internal and external connections are free of
leaks.
1) Open the water supply line shut-off valve.
2) Remove the front panel.
3) Move the control switch on the control box to the “ICE” position.
4) Replace the front panel in its correct position.
5) Turn on the power supply and allow the icemaker to operate for 5 minutes to ll up the
water tank.
6) Remove the front panel and move the control switch to the “SERVICE” position. Move
the service switch to the “WASH” position.
7) Replace the front panel in its correct position and allow the icemaker to run for 5
minutes.
8) Remove the front panel and move the service switch to the “DRAIN” position.
9) Replace the front panel in its correct position and allow the icemaker to drain for 2
minutes.
10) Turn off the power supply.
11) Remove the front panel and move the control switch to the “ICE” position.