12
11) Replace the water tank, cube guide, pump motor bracket, pump motor and oat switch
in their correct positions until they snap in place.
NOTICE
Be sure to let the discharge hose pass behind the copper tube and connect it
securely in position. See Fig. 3. Otherwise, the discharge hose may be caught
in the front insulation, leading to improper results.
12) Secure the pump motor bracket with the two thumbscrews.
13) Reconnect the pump motor connector and oat switch connector.
14) Replace the front insulation and front panel in their correct positions.
F. Electrical Connection
WARNING
1. Electrical connection must be hard-wired and must meet national, state,
and local electrical code requirements. Failure to meet these code
requirements could result in death, electric shock, serious injury, fire, or
severe damage to equipment.
2. This unit requires an independent power supply. See the nameplate for
proper voltage and breaker/fuse size. Failure to use a proper breaker or
fuse can result in a tripped breaker, blown fuse, or damage to existing
wiring. This could lead to heat generation or re.
3. THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the
icemaker could result in death or serious injury.
• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of
the nameplate rating.
• The white lead must be connected to the neutral conductor
of the power source. NOTICE! Miswiring may result in
severe damage to the icemaker. See Fig. 8.
• The opening for the power supply connection is 7/8” DIA to
t a 1/2” trade size conduit.
Fig. 8