User's Manual
14
F. Electrical Connection
WARNING
• Electrical connection must be hard-wired and must meet national, state, and local
electrical code requirements. Failure to meet these code requirements could result in
death, electric shock, serious injury, fi re, or damage.
• The appliance requires an independent power supply of proper capacity. See the
nameplate for electrical specifi cations. Failure to use an independent power supply of
proper capacity can result in a tripped breaker, blown fuse, damage to existing wiring,
or component failure. This could lead to heat generation or fi re.
• THE APPLIANCE MUST BE GROUNDED: Failure to properly ground the appliance
could result in death or serious injury.
• Electrical connection must be made in accordance with the instructions on the
“WARNING” tag, provided with the pig tail leads in the junction box. See Fig. 8.
• To reduce the risk of electric shock, do not touch the control switch with damp hands.
• Usually an electrical permit and services of a licensed
electrician are required.
• The maximum allowable voltage variation is ±10 percent
of the nameplate rating.
• The white lead must be connected to the neutral
conductor of the power source. NOTICE! Miswiring may
result in severe damage to the icemaker. See Fig. 8.
• The opening for the power supply connection is 7/8” DIA
to fi t a 1/2” trade size conduit.
Fig. 8
8"3/*/(
&-&$53*$"-$0//&$5*0/
5)*46/*5.645#&(306/%&%
'BJMVSFUPQSPQFSMZHSPVOEPSXJSF
UIJTVOJUDPVMESFTVMUJOEFBUI
TFSJPVTJOKVSZPSTFWFSFEBNBHF
UPUIFJDFNBLFS5IFXIJUFMFBE
NVTUCFDPOOFDUFEUPUIFOFVUSBM
DPOEVDUPSPGUIFQPXFSTPVSDF
4FFEJBHSBNCFMPX
"
+6/$5*0/#09
7
#308/
8)*5&
-
/