User's Manual
13
11) Replace the water tank, cube guide, pump motor bracket, pump motor and fl oat switch
in their correct positions until they snap in place.
NOTICE
Be sure to let the discharge hose pass behind the copper tube and connect it securely
in position. See Fig. 3. Otherwise, the discharge hose may be caught in the front
insulation, leading to improper results.
12) Secure the pump motor bracket with the two thumbscrews.
13) Reconnect the pump motor connector and fl oat switch connector.
14) Replace the front insulation and front panel in their correct positions.
Left Defl ector
Right Defl ector Thumbscrew
Thumbscrew
Collars
Collars
(Behind Left Defl ector)
Fig. 7