Service Manual

Table Of Contents
61
10. KM-1340MRJ with URC-14F
Specification Sheet
AC SUPPLY VOLTAGE 208-230/60/1 ( 3 WIRE WITH NEUTRAL FOR 115V)
AMPERAGE 14.0 A
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
ELECTRIC & WATER CONSUMPTIO
N
90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 2230 (4.54) 2070 (3.62)
WATER gal./24HR (gal./100 lbs.) 206 (17.5) 554 (40.4)
ICE PRODUCTION PER CYCLE 30.6 lbs. (13.9 kg) 1440pcs.
BIN CONTROL SYSTEM Thermostat
REFRIGERANT CHARGE TOTAL R404A, 11 lb. 0.4 oz. (5000g)
ICEMAKER, 6 lb. 9.8 oz. (3000g)
CONDENSER, 4 lb. 6.5 oz. (2000g)
Performance Data Sheet
70/21 1371 622
1314 596 1231 558
80/27 1328 602 1239 562 1153 523
90/32 1314 596 1177 534 1090 494
lbs./day kg./da
y
100/38 1296 588 1157 525 1010 458
70/21
80/27
90/32
watts 100/38
70/21 554 2.10
452 1.71 398 1.50
80/27 476 1.80 318 1.20 311 1.18
90/32 452 1.71 206 0.78 178 0.67
gal./day m
3
/day
100/38 335 1.27 199 0.75 152 0.57
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 203 14.3
221 15.5 242 17.0
80/27 217 15.2 245 17.2 264 18.6
90/32 221 15.5 265 18.6 285 20.1
PSIG kg/cm
2
G
100/38 224 15.8 270 19.0 304 21.4
70/21 47 3.3 50 3.5 51 3.6
80/27 49 3.4 53 3.7 54 3.8
90/32 50 3.5 56 3.9 57 4.0
PSIG kg/cm
2
G
100/38 49 3.5 56 4.0 58 4.1
19,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME 134 CU. IN. (URC-14-F)
3.2 2.3 2.1
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.7 4.0 3.7
4.2 3.1 3.1
4.0 2.3 2.2
33
30 34 35
30 34 36
2103 2230 2230
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
28 30 31
29 32
APPROXIMATE ELECTRIC
CONSUMPTION
2070 2117 2132
2106 2179 2167
2117 2230 2230
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10 70/21 90/32
ENG.F-011.1.0205