1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch No. 1 2 3 4 5 6 7 8 9 10
KM-350MAJ, KM-350MWJ OFF OFF OFF ON ON OFF ON OFF ON ON
KM-520MAJ, KM-520MWJ, KM-520MRJ OFF OFF OFF OFF OFF OFF ON OFF ON ON
KM-660MAJ, KM-660MWJ, KM-660MRJ OFF OFF OFF OFF OFF OFF ON OFF ON ON
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1 2 3 4 5
All Models OFF OFF OFF OFF ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5)
Pump-Out Time/Harvest Time During Pump-Out (3 & 4)
Harvest Time (1 & 2)
Factory Use (8)
Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (7)
(Do Not Adjust)
1 2 3 4 5 6 7 8 9 10
ON
S4 Dip Switch
1 2 3 4 5
ON
S5 Dip Switch
(Do Not Adjust)
Rell Counter (2 and 3)
Float Switch Selector (1)
Minimum Harvest Time (4)
Anti-Slush (5)
Harvest Pump Time (Harvest Assist) (6)