Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Harvest Time (S4 dip switch 1 & 2)
- 3. Pump-Out Time/Harvest Time During Pump-Out (S4 dip switch 3 & 4)
- 4. Pump-Out Frequency Control (S4 dip switch 5)
- 5. Harvest Pump Time (Harvest Assist) (S4 dip switch 6)
- 6. Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (S4 dip switch 7)
- 7. Factory Use (S4 dip switch 8)
- 8. Freeze Timer (S4 dip switch 9 & 10)
- 9. Pump-Out Pump Motor Direction (S5 dip switch 1)
- 10. Refill Counter (S5 dip switch 2 and 3)
- 11. Minimum Harvest Time (S5 dip switch 4)
- 12. Anti-Slush (S5 dip switch 5)
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
23
2a) 10-Min. Harvest Pump Time (Harvest Assist) with WV: CB "POWER OK" LED
blinking. CB LEDs 1, 4, and 3 are on and Comp, FMR, HGV, PM, and WV energize.
10-min. timer starts. Once 10-min. timer terminates, CB LEDs 1, 3, and 2 turn off and
Comp, FMR, HGV, and PM de-energize. WV continues.
2b) 10-Min. Fill: CB LED 4 on and WV energized. 10-min. timer starts.
2c) Final 10-Min. Harvest Pump Time (Harvest Assist) with WV: CB "POWER OK"
LED blinking. Once 10-min. timer terminates, CB LEDs 1, 4, and 3 are on and Comp,
FMR, HGV, and PM energizes. WV continues. 10-min. timer starts. Once 10-min. timer
terminates, normal freeze cycle begins. CB LED 1, 2, and 3 are on and Comp, FMR,
and PM continue. HGV and WV de-energize.
3) Appliance Cycle Reset and CB Alarm Reset:
Cycle Reset: Power supply or control switch turned off and on again: Appliance turns
off, then re-starts at 1. Fill Cycle.
Alarm Reset: CB "ALARM RESET" pressed during or after a freeze-time correction
cycle with power supply on: Appliance continues cycle with no interruption or reset.
CB red "POWER OK" LED blinking: CB red "POWER OK" LED resets to solid.
CB yellow "EXT HARVEST" LED blinking: CB yellow "EXT HARVEST: LED turns off.
Legend: BC–bin control; CB–control board; Comp–compressor; CR–compressor relay;
CT–control transformer; DV–drain valve; FM–fan motor; FMR–fan motor remote;
FS–oat switch; HGV–hot gas valve; HM–headmaster (C.P.R.); HPS–high-pressure
switch; L LV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve;
WRV–water regulating valve; WV–inlet water valve