8. Freeze Timer (S4 dip switch 9 & 10)
NOTICE
Adjust to proper specication, or the icemaker may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent
possible freeze-up issues. Upon termination of the freeze timer, the control board initiates
the harvest cycle or pump-out cycle. After 2 consecutive freeze timer terminations, the
control board shuts down the icemaker. In this case, see "II.J.3. Low Ice Production"
for possible solutions. The freeze timer is factory set and no adjustment is required.
Before changing this setting, contact Hoshizaki Technical Support at 1-800-233-1940 for
recommendations.
S4 Dip Switch Setting Time
(min.)
No. 9 No. 10
OFF OFF 60
OFF ON 50
ON OFF 70
ON ON 75
9. Pump-Out Pump Motor Direction (S5 dip switch 1)
NOTICE
Do not adjust. This must be left in the factory default position or the icemaker will
not operate correctly.
The pump-out pump motor direction setting determines pump motor rotation during
pump-out.
On models with a drain valve pump motor rotation doesn't change at pump-out.
Pump motor rotates in forward direction and drain valve is energized for pump-out.
On models with a check valve, pump motor rotation reverses at pump-out.
Pump motor rotates in reverse direction and opens check valve for pump-out.
S5 Dip Switch Setting
Pump-Out ComponentsNo. 1
OFF Pump Motor Forward Rotation and Drain Valve
ON Pump Motor Reverse Rotation and Check Valve