Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Harvest Time (S1 dip switch 1 & 2)
- 3. Pump-Out Time/Harvest Time During Pump-Out (S1 dip switch 3 & 4)
- 4. Pump-Out Frequency Control (S1 dip switch 5 & 6)
- 5. Harvest Pump Time Duration (Harvest Assist) (S1 dip switch 7 & 8)
- 6. Freeze Timer (S1 dip switch 9 & 10)
- 7. Pump-Out/Drain Selector (S2 dip switch 1)
- 8. Harvest Promotion Control (S2 dip switch 2)
- 9. Minimum Harvest Time (S2 dip switch 3)
- 10. Harvest Completion Detection Control (S2 dip switch 4)
- 11. Overfreeze Detection Control (S2 dip switch 5)
- 12. Slush Control (S2 dip switch 6)
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
19
Pump-Out Diagnosis:
In the freeze cycle before pump-out (see table above), after 5min. of freeze disconnect
FS connector. Check that CB LEDs 4, 5, 6, and 7are on, PM stops, then restarts, DV
energizes, and water is owing down the drain through DV. If not, continue to steps
below.
a) CB Diagnosis: Conrm FM de-energizes. If FM is energized with LEDs 4, 5, 6, and
7 on, replace CB. If PM does not stop and restart and DV does not energize, check
that CB LEDs 4, 5, 6, and 7 are on. Ifnot, replace CB. IfLEDs 4, 5, 6, and 7 are
on and PM is not energized, check for 115VAC at CB K5 #3 (DBU) to neutral(W).
If115VAC is not present, replace CB. If115VAC is present at CB K5 #3 (DBU) and
PM is not energized, continue to "b) PM Diagnosis:" below. If PM is energized and
DV is not energized, check for 115VAC at CB K5 #6 (GY) to neutral(W). If LED 4 is
on and 115VAC is not present at CB K5 #6 (GY), replace CB.
b) PM Diagnosis: Check for 115VAC CB K5 #3 (DBU) to neutral(W). If 115VAC is not
present, see "b) CB Diagnosis" above. Next, check for 115VAC at control switch
#4 (DBU) to neutral (W). If 115VAC is not present, conrm 115VAC at control switch
#5 (BK) to neutral (W). If 115VAC is present at control switch #5 (BK) and not at
control switch #4(DBU), replace control switch. If 115VAC is present at control
switch #4 (DBU) and PM is de-energized, check PM capacitor, motor winding, wiring
connections, and impeller for binding.
e) DV Diagnosis: Check for 115VAC at CB K5 #6 (GY) to neutral (W). If 115VAC is not
present, see "b) CB Diagnosis:" above. If 115VAC is present at CB K5 #6 (GY) and
DV is de-energized, check DV coil continuity, make sure the drain line is not clogged
and that DV is clean and operating properly.
8) Normal Harvest Cycle – Same as the initial harvest cycle. Return to step 5a) above.
Note: Appliance continues to cycle until BC is satised or power is switched off. The
appliance always restarts at the 1-min. ll cycle.
2. Shutdown Diagnosis
1) See "II.D.1. Bin Control Check."
Legend: BC–bin control; CB–control board; Comp–compressor; CR–compressor relay;
DV–drain valve; FM–fan motor; FS–oat switch; HGV–hot gas valve;
HPS–high-pressure switch; PM–pump motor; TXV–thermostatic expansion valve;
WRV–water regulating Valve; WV–inlet water valve