Service Manual
13
10 or 30sec 10 or 30sec 10 or 30sec 30 or 50sec 10 or 30sec
10 or 30sec
BIN FULLPART NAME
HARVEST CYCLE
(INITIAL)
FREEZE CYCLE HARVEST CYCLE FREEZE CYCLE
POWER SWITCH
ON
OFF
THERMISTOR
9°C
HARVEST CYCLE
(INCLUDING DRAIN)
OFF
HARVEST CYCLE
(AFTER BIN FULL)
FREEZE CYCLE
HARVEST CYCLE
Thermistor senses 9°C after more
than 8 min 30 sec in harvest cycle
HARVEST CYCLE
Thermistor senses 9°C
after 6 min to 8 min 30 sec
in harvest cycle
FREEZE CYCLE HARVEST CYCLE
6min
OFF
3min
1°C
COMPRESSOR
ON
OFF
FAN MOTOR
*KM-230BAJ, 300BAJ
ON
60sec
HOT GAS VALVE
ON
OFF
WATER VALVE
ON
OFF
PUMP MOTOR
[
KM-230BAJ] 30sec
[KM-300BAJ/BWJ] 10sec
ON
6min
DRAIN VALVE
ON
OFF
CLEANING VALVE
ON
OFF
FLOAT SWITCH
ON
OFF
BIN CONTROL
SWITCH
ON
OFF
CONTROLLER BOARD
RELAY: X1
(COMP)
ON
OFF
RELAY: X2
(HV/FM)
ON
OFF
RELAY: X3
(PM)
ON
OFF
RELAY: X4
(WV)
ON
OFF
RELAY: X6
(DV)
ON
OFF
Max 6 min
5 sec
Max 6 min Max 6 min
10 sec
Max 6 min
15 sec
10 sec
90 sec
Max 6 min
10 sec OFF, 50 sec ON 10 sec OFF, 50 sec ON 10 sec OFF, 50 sec ON
10℃ 10℃
10℃
10 sec OFF, 50 sec ON
10℃
Max 6 min Max 6 mi
n
2. Timing Chart