Specifications Sheet

KM-2200S_J3
3 PHASE STACKABLE ICE CUBER
KM-2200S_J3
05/31/17
Item # 13061
Item #:
Project:
Qty:
AIA#:
618 Hwy, 74 S., Peachtree City, GA 30269 | TEL 800-438-6087 | FAX 800-345-1325 | www.hoshizakiamerica.com
© HOSHIZAKI AMERICA, INC.
* approximate size in inches, image not to scale
Features
• Up to 2221 lbs. of ice production per 24 hours
• Stackable for 4442 lbs. per 24 hours ice production
in the same floor space
• Durable stainless steel exterior
• Protected by H-Guard Plus
Antimicrobial Agent
• EverCheck
TM
alert system
• R-404A Refrigerant
Water-Cooled 3 Phase
Shown on optional bin: B-900
KM-2200SWJ3
Individual crescent cube
Stainless steel evaporator
CycleSaver
TM
design
TM
TM
Remote Air-Cooled 3 Phase
KM-2200SRJ3
Available on Bins:
Warranty:
B-1500SS
B-1650SS
• Ambient Temp Range 45 - 100°F
• Water Temp Range 45 - 90°F
• Water Pressure 10 - 113 PSIG
• Voltage Range 187 - 253V
Operating Limits
Icemaker Water Supply Line: Minimum 3/8” Nominal ID
Copper Water Tubing or Equivalent
Icemaker Drain Line: Minimum 3/4” Nominal ID Hard
Pipe or Equivalent
Water-Cooled Model (Lines Must Be Independent of Icemaker)
Condenser Water Supply Line: Minimum 3/8” Nominal ID
Copper Water Tubing or Equivalent
Condenser Drain/Return Line: Minimum 3/8” Nominal ID Hard
Pipe (open drain system) or Copper Water Tubing (closed loop
system) or Equivalent
Plumbing
• Panels easily removed and all components
accessible for service.
• Allow 6” (15 cm) clearance at rear, sides, and top
for proper air circulation and ease of maintenance/
service.
Service
48" x 27
3/8
" x 36
7/16
"
W x D x H
Hoshizaki reserves the right to change specifications without notice.
®
B-800
B-900
Valid in United States, Canada, Puerto Rico and U.S. Territories.
Contact factory for warranty in other countries.
Top kit may be required.
See Bin Spec Sheets.
Printed in the U.S.A.
Air / Water Temp
Lbs. per 24 hours
Condenser
Model
70°/ 50°F 90°/ 70°F
ICE PRODUCTION
Per Cycle
Lbs. Cubes
Potable
Gal. per 100 lbs.
Condenser
Gal. per 100 lbs.
Max. Fuse Size
or HACR
Circuit Breaker
Heat
Rejection
BTU/hr.
Shipping
Weight
Voltage
ENERGY
STAR
®
WATER USAGE
90°/ 70°F 90°/ 70°F
ELECTRICAL
90°/ 70°F
kWh Used
per 100 lbs.
2221
2206
KM-2200SWJ3
KM-2200SRJ3
Water-Cooled
2200
2075
42.7
43
2160
2160
3.11
3.75
15.0
15.0
95
N/A
30A
20A
Remote Air-Cooled
27,200
26,700
440 lbs.
440 lbs.
208-230V/60/3
208-230V/60/3
12.8A
15.9A
Amperage
3 Phase
B-1150SS
B-1300SS
1
1/2
1/2
1
1/8
KM Edge Cube Dimensions*
KMEdge
DESIGN

Summary of content (2 pages)