Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Water/Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- A. Control Board Layout
- B. LED Lights and Audible Alarm Safeties
- C. Settings and Adjustments
- 1. Default Dip Switch Settings
- 2. Harvest Time (S1 dip switch 1 & 2)
- 3. Pump-Out Time/Harvest Time During Pump-Out (S1 dip switch 3 & 4)
- 4. Pump-Out Frequency Control (S1 dip switch 5 & 6)
- 5. Harvest Pump Time Duration (Harvest Assist) (S1 dip switch 7 & 8)
- 6. Freeze Timer (S1 dip switch 9 & 10)
- 7. Pump-Out/Drain Selector (S2 dip switch 1)
- 8. Harvest Promotion Control (S2 dip switch 2)
- 9. Minimum Harvest Time (S2 dip switch 3)
- 10. Harvest Completion Detection Control (S2 dip switch 4)
- 11. Overfreeze Detection Control (S2 dip switch 5)
- 12. Slush Control (S2 dip switch 6)
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
26
6) Remove the retainer clip from FS shaft, then remove the oat. Be careful not to damage
or lose the retaining clip when removing it. See Fig. 7.
7) Wipe down FS housing, shaft, oat, and retainer clip with a
mixture of 1 part Hoshizaki "Scale Away" and 25 parts warm
water. Rinse the parts thoroughly with clean water.
8) Reassemble FS assembly, then replace and secure the
removed parts in the reverse order of the removal procedure.
9) Replace the upper rear and top panels.
10) Plug the icemaker into the electrical outlet.
11) Move the control switch to the "ICE"
position to start the automatic icemaking
process.
12) Replace the louver in its correct position.
Legend: CB–control board; FS–oat switch
2. Float Switch Cleaning
Depending on local water conditions, scale may build up on FS. Scale on the switch can
cause the oat to stick. In this case, FS should be cleaned.
1) Remove the louver, move the control switch to the "OFF" position, then unplug the
icemaker from the electrical outlet.
2) Disconnect the silicone hose to drain the water, then after all the water has drained
reconnect the silicone hose back in its correct position. See Fig. 4.
3) Remove the top and upper rear panels.
4) Disconnect the FS/CB 2-pin connector (1 black (BK) wire and 1 red (R) wire coming
from FS and 2 red (R) wires coming from CB K1 connector pins 1 and 3).
KM-81BAJ, KM-116BAJ
5) Remove the water tank. Next, remove the screw securing the FS, then remove the FS.
See Fig. 5.
KM-161BAJ, KM-161BWJ
5) Locate the FS behind the pump motor. Next, as shown in Fig. 6 pinch the FS bracket
where indicated (1) and pull it forward diagonally (2) to unhook the FS, then remove the
screw securing the FS to the bracket.
Fig. 5
Float Switch
Float Switch
Housing
Float Switch
Float
Float Switch
Shaft
Float Switch
Retainer Clip
Fig. 7
Float Switch
Mounting Screw
Fig. 6
Float Switch
Float Switch
Bracket