2. Shutdown Flow Chart
Shutdown Flow Chart
1. Bin Full
Shutdown Delay:
Fill Cycle–15 sec. after activation.
Harvest Cycle15 sec. after the next
freeze cycle starts.
Freeze Cycle–15 sec. after activation
if activated at least
15 sec. before the 5-min.
short cycle protection
timer terminates.
Otherwise, at the end of the
next harvest cycle.
Shutdown
and Restart
BC Operation
BC open
(BC actuator paddle engaged)
Red "POWER OK" LED ashing
BC open
Red "POWER OK"
LED ashing.
FS opens or
5-min. timer terminates
DV de-energizes
3. Icemaker Off
Minimum off time:
90-sec. minimum
90-sec. off timer terrminates
before the appliance can
restart.
4. Ice Level Lowered
Icemaker starts at
"1. 1-Minute Fill Cycle."
BC closed
(BC actuator paddle disengaged)
Red "POWER OK" LED on solid
To 1. 1-Minute Fill Cycle
Legend:
BC–bin control
DV–drain valve
FS–oat switch
2. Water Tank Drain
2 sec. after all components
de-energize, DV energizes
for a max. of 5 min. or until
the FS opens.
BC open
Red "POWER OK" LED ashing
All components de-energized
DV-energized after 2 sec.