Instruction Manual

1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper
Water Tubing or Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal ID Hard
Pipe or Equivalent
An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 4
KM-81BAJ, KM-116BAJ, KM-161BAJ
2-inch (5-cm)
air gap
Drain
Floor
Icemaker Water Supply
Inlet 1/2” FPT
Icemaker Drain Outlet
3/4” FPT
Shut-o󰀨 Valve
To approved
oor drain
Drain Valve
1/4” fall
per foot
Minimum 3/4” Nominal ID
Hard Pipe or Equivalent
Minimum 1/4” Nominal ID Copper
Water Tubing or Equivalent
Trap
Be sure there is su󰀩cient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Vent Tube
17