Service Manual

Table Of Contents
18
3. Freeze-Time Correction Chart
Legend:
Comp–compressor
FM–fan motor
FMR–fan motor-remote
HGV–hot gas valve
PM–pump motor
WV–inlet water valve
2A7664-02 Freeze-Time Correction Flow Chart
1. 10-Minute Harvest Cycle with WV
• Do not adjust S4 dip switch 7 out of the factory position.
After step 2 completes 4th sequence (80 min. completed),
repeat step 1 for 5th and nal time.
Cycle Steps
Steps 1 and 2 repeat
4 times (total 80 min.),
then step 1 repeats for
a 5th time to complete
Freeze-Time Correction
Cycle.
2. 10-Minute Fill/Overow
Comp energized
FMR energized
HGV energized
PM energized
WV energized
WV energized
Comp de-energized
FMR de-energized
HGV de-energized
PM de-energized
Start
After 5th 10-Minute Harvest Pump Cycle with WV
Freeze-Time Correction Cycle Complete.
Go to Step "3. Freeze Cycle" in Operation Flow Chart.
Freeze Time Differential Exceeded.
Minimum and Maximum Freeze times
have exceeded differential parameters.
Freeze-Time Correction function is
enabled when S4 Dip Switch 7 is in the
"ON" position. CB monitors freeze time.
After 3freeze cycles, CB compares the
minimum and maximum differential of
the 3 freeze cycle times. Every freeze
cycle time after the third freeze cycle
time is added to the minimum/maximum
calculation.
Example: After 8 cycles, if the differential
between the shortest cycle (minimum)
and the longest cycle (maximum) is equal
to or greater than 427 sec. a freeze-time
correction cycle is initiated:
Number of
Freeze Cycles
Differential
Value in Sec.
3 254
4 309
5 349
6 380
7 406
8 427
9 446
10 462
Note: When 1st freeze-time correction
cycle is initiated, CB "POWER OK"
LED starts blinking. On 2nd freeze-time
correction cycle, if CB "POWER OK"
LED has been reset, CB "POWER OK"
LED starts blinking. If CB "POWER OK"
had not been reset after 1st freeze-time
correction cycle CB "POWER OK" LED
continues to blink.
After 3rd freeze-time correction cycle in
36hours, CB yellow "EXT HARVEST"
LED starts blinking.
Appliance continues to operate and LEDs
continue to blink until ALARM RESET
button is pressed with power on.
Appliance Cycle Reset and Alarm Reset:
Cycle Reset: Power Supply or Control Switch Turned Off and On
again: Appliance turns off, then re-starts at 1.Fill Cycle.
Alarm Reset: CB "ALARM RESET" pressed during or after a
freeze-time correction cycle with power supply on:
Appliance continues cycle with no interruption or reset.
CB red "POWER OK" LED blinking:
CB red "POWER OK" LED resets to solid.
CB yellow "EXT HARVEST" LED blinking:
CB yellow "EXT HARVEST: LED turns off.