8. KM-1601SAJ3
Specification Shee
t
AC SUPPLY VOLTAGE 208-230/60/3
AMPERAGE 12.9 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 2590 (4.40) 2320 (3.68)
WATER gal./24HR (gal./100 lbs.) 297 (21.0) 242 (16.0)
ICE PRODUCTION PER CYCLE 30.9 lbs. (14 kg) 1440pcs.
BIN CONTROL SYSTEM Mechanical
REFRIGERANT CHARGE R404A, 5 lb. 1.1 oz. (2300g)
Performance Data Shee
t
70/21 1513 686 1484 673 1393 632
80/27 1491 676 1446 656 1327 602
90/32 1484 673 1414 641 1305 592
lbs./day kg./day
100/38 1449 657 1388 630 1205 547
70/21
80/27
90/32
watts 100/38
70/21 242 0.92 258 0.98 223 0.84
80/27 254 0.96 279 1.06 212 0.80
90/32 258 0.98 297 1.12 243 0.92
gal./day m
3
/day
100/38 258 0.98 284 1.08 193 0.73
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 255 17.9
275 19.3 307 21.6
80/27 270 19.0 300 21.1 335 23.6
90/32 275 19.3 322 22.6 356 25.1
PSIG kg/cm
2
G
100/38 283 19.9 330 23.2 388 27.3
70/21 38 2.7 40 2.8 43 3.0
80/27 40 2.8 43 3.1 45 3.2
90/32 40 2.8 46 3.2 48 3.4
PSIG kg/cm
2
G
100/38 41 2.8 46 3.3 50 3.5
16,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 3,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10 70/21 90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2320 2399 2433
2380 2503 2495
2399 2590 2600
2381 2592 2610
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
24 26 28
25 27 30
26 29 31
26 29 33
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.6 4.0 3.6
4.1 3.1 3.1
4.0 2.4 2.2
3.2 2.3 2.1
HEAD PRESSURE
SUCTION PRESSURE
ENG.F-011.1.0205