Service Manual

41
B. Component Service Information
NOTICE
When replacing a component listed below, see the notes to help ensure proper
operation.
Component Notes
Compressor 1 phase: Install a new start capacitor, run capacitor, and start relay.
Thermostatic
Expansion Valves
Attach the thermostatic expansion valve bulb to the suction line in the same location
as the previous bulb.
The bulb should be between the 10 and 2 o'clock positions on the tube.
• Secure the bulb with the clamp and holder, then insulate it.
Hot Gas Valves
Liquid Line Valves
• Replace the strainer if applicable.
• Use copper tube of the same diameter and length when replacing valve lines.
Fan Motors Install a new capacitor.
Pump Motor Install a new capacitor.
Thermistor Attach the new thermistor to the suction line in the same location as the previous
thermistor.
The thermistor should be at the 12 o'clock position on the tube.
• Smoothly ll the recessed area of the thermistor holder with high thermal
conductive type sealant. Hoshizaki America part number 4A0683-01 (Silicone
Heat Sink Compound 10-8108 manufactured by GC Electronics), KE-4560 RTV
(manufactured by ShinEtsu Silicones), or equivalent are recommended.
• Secure the thermistor with the holder, then insulate it.
• Be very careful to prevent damage to the leads.