6. KM-1100MWJ
Specification Shee
t
AC SUPPLY VOLTAGE 208-230/60/1
AMPERAGE 9.6 A
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1680 (4.00) 1610 (3.60)
WATER gal./24HR (gal./100 lbs.) 201 (20.0) 395 (36.8)
WATER COOLED CONDENSER 1076 (107) 653 (61)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE 19.5 lbs. (8.8 kg) 960pcs.
BIN CONTROL SYSTEM Thermostatic
REFRIGERANT CHARGE R404A, 1 lb. 10.5 oz. (750g)
Performance Data Shee
t
70/21 1073 487 1054 478 1008 457
80/27 1058 480 1028 466 972 441
90/32 1054 478 1006 456 954 433
lbs./day kg./da
y
100/38 1038 471 994 451 906 411
70/21
80/27
90/32
watts 100/38
70/21 1048 3.97
1115 4.22 1538 5.82
80/27 1099 4.16 1204 4.56 1811 6.85
90/32 1115 4.22 1278 4.84 1816 6.87
gal./day m
3
/day
100/38 1357 5.14 1404 5.31 2310 8.75
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 243 17.1
246 17.3 255 18.0
80/27 245 17.2 250 17.6 262 18.4
90/32 246 17.3 253 17.8 264 18.6
PSIG kg/cm
2
G
100/38 250 17.6 256 18.0 275 19.3
70/21 51 3.6 52 3.7 58 4.1
80/27 52 3.6 54 3.8 62 4.4
90/32 52 3.7 55 3.9 62 4.4
PSIG kg/cm
2
G
100/38 55 3.8 57 4.0 69 4.9
17,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 2,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER 91 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE less than 10 PSIG
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10 70/21 90/32
APPROXIMATE ELECTRIC
CONSUMPTION
1610 1631 1661
1626 1658 1689
1631 1680 1711
1637 1687 1740
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
24 24 25
24 25 26
24 26 27
25 26 28
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
3.2 2.9 2.7
2.9 2.4 2.5
2.9 2.0 2.0
2.5 2.0 2.0
HEAD PRESSURE
SUCTION PRESSURE
ENG.F-011.1.0205