Instruction Manual

9
3. KM-600MAH
Single Phase
Model Number KM-600MAH
AC Supply Voltage 115-120/60/1
Compressor 115-120V 10.3RLA 70LRA
Pump 120V 0.5FLA 10W
Fan 120V 1.0FLA 50W
Other 115-120V 0.2A
Maximum Fuse Size 15 AMPS
Max. HACR Breaker
(USA Only)
15 AMPS
Max. Circuit Breaker
(Canada Only)
15 AMPS
Minimum Circuit
Ampacity
15 AMPS
Design Pressure HI - 467PSI LO - 230PSI
Refrigerant 404A 1 LB. 11 OZ.
4. KM-650M_H
Single Phase
Model Number KM-650MAH KM-650WH KM-650MRH
AC Supply Voltage 208-230/60/1 208-230/60/1 208-230/60/1
Compressor 208-230V 6.0RLA
36LRA
208-230V 5.0RLA
36LRA
208-230V 6.1RLA 36LRA
Pump 120V 0.5FLA 10W 120V 0.5FLA 10W 120V 0.5FLA 10W
Fan 120V 1.0FLA 30W --- --- --- 120V 3A MAX (Fan in URC)
Other 115-120V 0.15A 115-120V 0.15A 115-120V 0.3A
Maximum Fuse Size 15 AMPS 15 AMPS 15 AMPS
Max. HACR Breaker
(USA Only)
15 AMPS 15 AMPS 15 AMPS
Max. Circuit Breaker
(Canada Only)
15 AMPS 15 AMPS 15 AMPS
Minimum Circuit
Ampacity
15 AMPS 15 AMPS 15 AMPS
Design Pressure HI - 467PSI
LO - 230PSI
HI - 427PSI
LO - 230PSI
HI - 467PSI LO - 230PSI
Refrigerant 404A 1 LB. 8 OZ. 404A 1 LB. 5.2 OZ. 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-5F: 5 LB. 14.9 OZ.