Service Manual

50
B. Performance Data
Pressure data is recorded at 5 min. into freezing cycle.
A
PPROXIMATE Ambient Water Temp. (°F)
ICE PRODUCTION PER 24 HR. Temp. (°F) 50 70 90
70 50(23) 47(21) 44(20)
80 49(22) 46(21) 43(20)
90 47(21) 45(20) 42(19)
lbs./day (kg/day) 100 44(20) 42(19) 39(18)
A
PPROXIMATE ELECTRIC 70 270 280 290
CONSUMPTION 80 280 285 295
90 285 295 305
watts 100 300 310 320
A
PPROXIMATE WATE
R
70 271(1.02) 75(0.28) 70(0.27)
CONSUMPTION PER 24 HR. 80 254(0.96) 72(0.27) 67(0.25)
90 242(0.92) 69(0.26) 65(0.25)
gal./day (m
3
/day) 100 227(0.86) 64(0.24) 61(0.23)
FREEZING CYCLE TIME 70 30.7 34.2 36.9
80 33.7 36.7 40.0
90 36.1 39.0 42.2
m i n . 100 39.5 43.3 46.1
HARVEST CYCLE TIME 70 9.7 10.2 10.4
80 9.3 9.6 9.6
90 9.0 9.2 9.2
m i n . 100 8.6 8.7 8.7
HEAD PRESSURE 70 110(0.75) 119(0.82) 126(0.87)
80 131(0.90) 141(0.97) 149(1.03)
90 152(1.05) 165(1.14) 171(1.18)
PSIG (MPa) 100 178(1.23) 189(1.30) 197(1.36)
SUCTION PRESSURE 70 17(0.12) 22(0.15) 28(0.19)
80 20(0.14) 23(0.16) 29(0.20)
90 20(0.14) 24(0.17) 29(0.20)
PSIG (MPa) 100 23(0.16) 26(0.18) 30(0.21)
TOTAL HEAT OF REJECTION 2600 BTU/h (AT 90°F / WT 70°F)