Service Manual

49
VIII. Technical Information
We reserve the right to make changes in specications and design without prior notice.
A. Specication Data
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 5.0A ( 5 Min. Freeze AT 104
°F / WT 80°F )
MINIMUM CIRCUIT AMPACITY N/A
MAXIMUM FUSE SIZE N/A
APPROXIMATE ICE PRODUCTION
PER 24 HR.
lbs./day ( kg/day )
Ambient Water Temp. (°F)
Temp. (°F) 50 70 90
70 50 (23) 47 (21) 44 (20)
80 49 (22) 46 (21) 43 (20)
90 47 (21) 45 (20) 42 (19)
100 44 (20) 42 (19) 39 (18)
SHAPE OF ICE Ball φ45mm
ICE PRODUCTION PER CYCLE 1.48 Ibs (0.67kg),15pcs.
APPROXIMATE STORAGE CAPACITY 36 Ibs (16.2kg)
ELECTRIC & WATER CONSUMPTION 90°F / 70°F 70°F / 50°F See details of
ELECTRIC W (kWh/100 lbs.) 295(15.7) 270(13.0) PERFORMANCE DATA
WATER gal./24HR (gal./100 lbs.) 69(153) 271(542) NO.SS-
EXTERIOR DIMENSIONS ( W x D x H ) 24.8” x 20.7” x 33.5” (630×525×850mm)
EXTERIOR FINISH Stainless Steel Galvanized Steel ( Rear )
WEIGHT Net 139 Ibs (63kg). Shipping 150 Ibs (68kg)
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet R 1/2” (connected at rear side)
- DRAIN Outlet Rc3/4” (connected at rear side)
CUBE CONTROL SYSTEM Thermistor and Timer
HARVESTING CONTROL SYSTEM Hot gas, Thermistor and Timer
ICE MAKING WATER CONTROL Timer Controlled
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Level Switch with Delay
COMPRESSOR Hermetic. Model FF8.5GX
CONDENSER Fin and Tube, type Air-cooled
EVAPORATOR Tin-plated Copper Tube on Sheet and Cells
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 7.1 oz. (200 g)
COMPRESSOR PROTECTION Auto-reset Overload Protector
ACCESSORIES - SUPPLIED Ice Scoop
- REQUIRED N/A
OPERATION CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100
°F
WATER SUPPLY TEMP. 45 - 90
°F
WATER SUPPLY PRESS. 7 - 113 PSIG