Instruction Manual

E. Electrical Connection
WARNING
• Electrical connection must be hard-wired and must meet national, state, and local
electrical code requirements. Failure to meet these code requirements could result
in death, electric shock, serious injury, re, or damage.
The icemaker requires an independent power supply of proper capacity. See
the nameplate for electrical specications. Failure to use an independent power
supply of proper capacity can result in a tripped breaker, blown fuse, damage to
existing wiring, or component failure. This could lead to heat generation or re.
THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the
appliance could result in death or serious injury.
• Electrical connection must be made in accordance with the instructions on the
"WARNING" tag, provided with the pig tail leads in the junction box. See Fig. 3.
• Usually an electrical permit and services of a licensed
electrician are required.
The maximum allowable voltage variation is ±10
percent of the nameplate rating.
The white lead must be connected to the neutral
conductor of the power source. NOTICE! Miswiring
may result in severe damage to the icemaker.
The opening for the power supply connection is
7/8” DIA to t a 1/2” trade size conduit.

8"3/*/(
&-&$53*$"-$0//&$5*0/
5)*46/*5.645#&(306/%&%
'BJMVSFUPQSPQFSMZHSPVOEPSXJSF
UIJTVOJUDPVMESFTVMUJOEFBUI
TFSJPVTJOKVSZPSTFWFSFEBNBHF
UPUIFJDFNBLFS5IFXIJUFMFBE
NVTUCFDPOOFDUFEUPUIFOFVUSBM
DPOEVDUPSPGUIFQPXFSTPVSDF
4FFEJBHSBNCFMPX
"YYYY#BTFEPO
+6/$5*0/#09
7
#308/
8)*5&
-
/
Fig. 3