Instruction Manual
10
10) Level the icemaker and storage bin in both the left-to-right and front-to-rear directions.
Adjust the storage bin legs to make the icemaker level.
11) Replace the panels in their correct positions.
E. Electrical Connection
WARNING
1. Electrical connection must be made in accordance with the instructions on
the “WARNING“ tag, provided with the pig tail leads in the junction box.
2. Electrical connection must be hard-wired and must meet national, state,
and local electrical code requirements. Failure to meet these code
requirements could result in death, electric shock, serious injury, fire, or
severe damage to equipment.
3. This unit requires an independent power supply. See the nameplate for
proper voltage and breaker/fuse size. Failure to use a proper breaker or
fuse can result in a tripped breaker, blown fuse, or damage to existing
wiring. This could lead to heat generation or fi re.
4. THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the
icemaker could result in death or serious injury.
• Use copper supply wires. The smallest conductor that the
installer may use for branch circuit wiring is 14 AWG (2.1
mm
2
) wire.
• The maximum allowable voltage variation is ±10 percent of
the nameplate rating.
• The white lead must be connected to the neutral conductor of
the power source. NOTICE! Miswiring may result in severe
damage to the icemaker. See Fig. 3.
• The opening for the power supply connection is 7/8” DIA to fi t
a 1/2” trade size conduit.
• Usually an electrical permit and services of a licensed
electrician are required.
8"3/*/(
&-&$53*$"-$0//&$5*0/
5)*46/*5.645#&(306/%&%
'BJMVSFUPQSPQFSMZHSPVOEPSXJSF
UIJTVOJUDPVMESFTVMUJOEFBUI
TFSJPVTJOKVSZPSTFWFSFEBNBHF
UPUIFJDFNBLFS5IFXIJUFMFBE
NVTUCFDPOOFDUFEUPUIFOFVUSBM
DPOEVDUPSPGUIFQPXFSTPVSDF
4FFEJBHSBNCFMPX
"YYYY#BTFEPO
+6/$5*0/#09
7
#308/
8)*5&
-
/
Fig. 3