User's Manual
9
The unit will continue through the
freeze and harvest cycle until the bin
control shuts down the refrigeration
system.
When pushed over, the bin control
has a 10-second delay before shut
down occurs. An 85-second delay
occurs at startup when the bin
control is released.
Now let’s take a look at the control
board adjustments. Remember that
the adjustments are factory set to
provide proper operation in normal
operating conditions.
NO SEASONAL
ADJUSTMENTS!
The board adjustments are made
through variable resistors on the
board. The cube control is marked
VR5. This adjusts the thermistor
switching temperature of - 9.4°F and
the length of the freeze cycle. The
dimple size in the cube also changes.
Adjusting to a larger dimple will
result in a shorter freeze cycle and a
smaller cube. A smaller dimple
setting will result in a longer cycle
and a larger cube. The factory
setting is 5.