CONTROLS AND ADJUSTMENTS
DEFROST SELECTOR
STEPS TO CHANGE SETPOINT
1. To access the menu press the “Set” buon unl the value “0” is
displayed on the screen.
2. Release the “Set” buon.
3. Press the “Up” buon repeatedly unl the value 22 is displayed
on the screen. This is the password.
4. Push the “Set” buon once to access the menu.
5. When you access the menu the display shows the leers “PS”.
6. Press the “Up” buon repeatedly unl “St appears in the
display, then press the “Set” buon.
7. The display shows the value of the current setpoint.
8. Change the value of the Set Point using the “Up” or “Down”
buon.
9. To save the new Set Point, press the “Set” buon unl the
display shows the current temperature.
NOTES:
- THE DEFAULT SET POINT IS 34°F.
- THE SET POINT RANGE IS FROM 28°F TO 40°F.
ALARM SAFETIES
Alarm signals are designed to protect the appliance and items inside. These
alarms give informaon or warnings in the event the appliance is operang out
of acceptable parameters. Should one of the alarms accur, follow the instrucons
below to address the alarm. The alarm icon appears on the display and the
alarm code alternates with the cabinet temperature. For high temperature, low
temperature, and door alarms, the appliance beeps in addion to displaying the
alarm icon and alarm code.