Instruction Manual

7
2) Position the showcase in a selected site. Clean the interior with soap and water and
rinse thoroughly.
3) Level the showcase in both the left-to-right and the front-to-rear directions.
4) The perimeter where the machine touches the counter should be sealed with silicone.
D. Electrical Connections
* The showcase requires an independent power supply of proper capacity. See the
nameplate for electrical speci cations. The maximum allowable voltage variation is ±10
percent of the nameplate rating.
* THE SHOWCASE MUST BE GROUNDED. The showcase is equipped with a NEMA
5-15 three-prong grounding plug to reduce the risk of potential shock hazards. It must be
plugged into a properly grounded, independent 3-prong wall outlet.
E. Drain Connections
* The hose may be connected to either right or left joint, whichever is convenient.
* Keep more than 2 vertical inch (5 vertical cm) air gap between the drain hose end and
the oor drain or sink.
Fig. 5
2” (5 cm)
Plug
Plug
Joint
Joint
Hose