Instruction Manual

11
C. Air Filter
A plastic mesh air lter removes dirt or dust from the
air, and keeps the condenser from getting clogged. If
the filter gets clogged, the showcase’s performance
will be reduced. Check the lter at least twice a month.
When clogged, use warm water and a neutral cleaner
to wash the lter.
1) Hold the tabs located at the bottom of the louver,
and lift them up to release the louver from the body.
2) Pull the louver toward you.
3) Pull the louver downward.
4) Grasp the frame of the air lter, and pull it toward
you.
5) Clean the air lter.
6) Re t the air lter and louver in the reverse order of
the removal procedure.
D. Condenser
Check the condenser once a year, and clean if required by using a brush or vacuum
cleaner. More frequent cleaning may be required depending on the location of the
showcase.
E. Checking Ground Fault Circuit Interrupter
Push the test button at least once a month, and simulate a ground fault on the load circuit.
Fig. 6
Louver
Air Filter
4
Condenser