Service Manual

41
5. Bin Control Selector (S1 dip switch 7)
The appliance is factory set for infrared sensor bin control operation. No adjustment is
required. In the factory default position (S1 dip switch 7 in the on position), the gear motor
delay after the upper oat switch closes is 30 sec. WARNING! Do not place S1 dip
switch 7 in the off position. This could lead to icemaker movement or ice overow.
S1 Dip Switch
Setting
Bin Control Application Gear Motor Delay
No. 7
OFF BC2 (mechanical stand-alone) (Standard Ice Storage Bins Only) 5 seconds
ON
BC1 (infrared sensor) Stand-Alone and
BC1 (infrared sensor) with BC2 (mechanical backup)
30 seconds
6. BC2 (Mechanical Backup) Shutdown Delay (S1 dip switch 8)
Not available when S1 dip switch 7 is on. Factory set for normal operation. No adjustment
is required. This appliance does not utilize a mechanical bin control.
S1 Dip Switch Setting
Mechanical Bin Control
Shutdown Delay
No. 8
OFF 0.25 Seconds
ON 6.7 Seconds
7. Shutdown Sequence (S1 Dip Switch 9)
Factory set for optimum performance. Do not adjust.
S1 Dip Switch
Setting
Shutdown Sequence
No. 9
OFF
Slow timing (90s after Mechanical Bin Control delay is satised, the COMP shuts
down; after an additional 60s, the GM shuts down)
ON
Fast timing (after Mechanical Bin Control delay is satised both COMP & GM shuts
down at the same time)
8. Alarm Selection (S1 Dip Switch 10)
Factory set for optimum performance. Do not adjust.
S1 Dip Switch Setting
Shutdown Sequence
No. 10
OFF Beep
ON No Beep, power LED blinks with the number of error code